inomed Medizintechnik GmbH
inomed Xpert plusWith the IOM system family, inomed offers a complete package of products for multimodal intraoperative neuro­physiological monitoring. The systems impress with their performance, user-friendliness, flexibility and variety of applications.
inomed Xpert plusinomed Xpert plus
inomed Xpert plusWith the IOM system family, inomed offers a complete package of products for multimodal intraoperative neuro­physiological monitoring. The systems impress with their performance, user-friendliness, flexibility and variety of applications.

The Xpert plus is ideal for advanced monitoring. The system is fully equipped as standard and can be used directly for modalities such as AEP, VEP or pelvic IONM. The height-adjustable monitor enables adaptation to the respective user and ensures good ergonomics. Thanks to its modular design, the Xpert plus can easily be expanded up to 64 channels and is therefore suitable for various IONM applications.


Variants
inomed Xpert plus 32-channel system for neurosurgery
Item no.: 504004-32CHinomed Xpert plus 32-channel system for neurosurgeryThe powerful Xpert plus combines mobility with functionality. It consists of an equipment cart with panel PC, height-adjustable monitor, laser printer, keyboard drawer, two large accessory drawers, constant-current stimulator, amplifier with a total of 32 recording channels (56 inputs: 8 referential and 48 differential) and all necessary adapter boxes.
Available
Go to product page
Add to watch list
Software modules
Software DataSync
Item no.: 504400Software DataSyncFor storing and accessing neuro­monitoring data from multiple systems via a central server
Available
Add to watch list
Software Screen2Video
Item no.: 504415Software Screen2VideoFor recording a desktop video of the NeuroExplorer application, e.g. for documentation and training purposes
Available
Add to watch list
Software Multi-channel Video
Item no.: 504418Software Multi-channel VideoFor displaying up to four video sources on the measurement screen, including recording function
Available
Add to watch list
Software Scalp-EEG
Item no.: 504423Software Scalp-EEGFor recording an electroencephalogram (EEG) and local field potential (LFP) as a raw signal and spectral analysis (CSA/DSA) for software version 8
Available
Add to watch list
Analysis Software
Item no.: 504401Analysis SoftwareFor viewing and analyzing neuro­physio­logical measurements on a PC
Available
Add to watch list
Software EMG
Item no.: 504402Software EMGFor recording free-running and triggered elecromyography measurements (EMG)
Available
Add to watch list
Software Channel Select
Item no.: 504403Software Channel SelectFor selecting the best EMG signal when using the ALM Tube or Laryngeal Electrode Select
Available
Add to watch list
Software AEP
Item no.: 504404Software AEPFor recording auditory evoked potentials (AEP)
Available
Add to watch list
Software SEP
Item no.: 504406Software SEPFor recording somatosensory evoked potentials (SEP)
Available
Add to watch list
Software MEP
Item no.: 504408Software MEPFor recording motor evoked potentials (MEP)
Available
Add to watch list
Software Spine
Item no.: 504409Software SpineFor automated pedicle stimulation using triggered EMG
Available
Add to watch list
Software VEP
Item no.: 504410Software VEPFor recording visual evoked potentials (VEP)
Available
Add to watch list
Software EEG
Item no.: 504414Software EEGFor recording an electroencephalogram (EEG) or an electrocorticogram (ECoG), for software version 6 and 7
Available
Add to watch list
Software TOF
Item no.: 504407Software TOFFor performing an automated train-of-four measurement for muscle relaxation measurement
Available
Add to watch list
Software ECoG
Item no.: 504424Software ECoGFor recording an electroencephalogram (EEG) or an electrocorticogram (ECoG)
Available
Add to watch list
Video interface for IOM incl. software and hardware
Item no.: 540013Video interface for IOM incl. software and hardwareConsisting of a video software license for NeuroExplorer software, Magewell USB Capture AIO and BNC interface
Available
Add to watch list
Extensions
Headbox 8 Ch. DIF-8 Ch. REF-AEP
Item no.: 504285Headbox 8 Ch. DIF-8 Ch. REF-AEPEnables the recording of 8 referential, 8 differential channels and the AEP stimulator. Can be combined with: 540340, 540523, 540525, 540531
Available
Add to watch list
Headbox 16 Ch. REF-AEP
Item no.: 504281Headbox 16 Ch. REF-AEPEnables the recording of 16 referential channels and the stimulation of AEPs. Can be combined with: 540522, 540524
Available
Add to watch list
Headbox 16 Ch. DIF
Item no.: 504271Headbox 16 Ch. DIFEnables the recording of 16 differential channels. Can be combined with: 520302, 540531, 540532, 540533, 540534, 540535
Available
Add to watch list
Headbox 16 Ch. REF
Item no.: 504261Headbox 16 Ch. REFEnables the recording of 16 referential channels. Can be combined with: 540524
Available
Add to watch list
EP Adapter for Headbox 8 Ch. DIF-8 Ch. REF-AEP
Item no.: 540523EP Adapter for Headbox 8 Ch. DIF-8 Ch. REF-AEPFor maximal 8-channel recording to a common reference and the possibility to connect AEP Earphones (540340). Can be combined with: 504285, 540559
Available
Add to watch list
EP Adapter for Headbox 16 Ch. REF-AEP
Item no.: 540522EP Adapter for Headbox 16 Ch. REF-AEPFor maximal 16-channel recording to a common reference and the possibility to connect AEP Earphones (540340). Can be combined with: 504281, 504261, 540560
Available
Add to watch list
EP Adapter for Headbox 8 Ch. DIF-8 Ch. REF-AEP
Item no.: 540525EP Adapter for Headbox 8 Ch. DIF-8 Ch. REF-AEPFor maximal 8-channel recording to a common reference. Can be combined with: 504285, 540559
Available
Add to watch list
EP Adapter for Headbox 16 Ch. REF
Item no.: 540524EP Adapter for Headbox 16 Ch. REFFor maximal 16-channel recording to a common reference. Can be combined with: 504281, 504261, 540560
Available
Add to watch list
EMG/MEP Adapter Ch. 1-8 for 504271 for Headbox 16 Ch. DIF
Item no.: 540531EMG/MEP Adapter Ch. 1-8 for 504271 for Headbox 16 Ch. DIFFor maximal 8-channel differential recording.
Available
Add to watch list
EMG/MEP Adapter Ch. 9-16 for 504271 for Headbox 16 Ch. DIF
Item no.: 540532EMG/MEP Adapter Ch. 9-16 for 504271 for Headbox 16 Ch. DIF For maximal 8-channel differential recording.
Available
Add to watch list
EMG/MEP Adapter Ch. 1-8 for 504271 for color-coded accessories
Item no.: 540533EMG/MEP Adapter Ch. 1-8 for 504271 for color-coded accessoriesFor maximal 8 color-coded differential recording channels.
Available
Add to watch list
MEP Stimulation Adapter for Grid/TES Stimulation Matrix
Item no.: 540510MEP Stimulation Adapter for Grid/TES Stimulation MatrixFor 8-channel high-current stimulation for connection to Grid/TES Stimulation Matrix. Can be combined with: 504180, 540559, 540560
Available
Add to watch list
Accessories
AEP Insert Earphones for IOM systems and NeMo
Item no.: 540340AEP Insert Earphones for IOM systems and NeMoFor IOM systems with range of earplugs in three different sizes, silicon tubes red and blue, cable length 2 m, with Redel connector yellow, delivered non-sterile, not autoclavable
Available
Add to watch list
Item no.: 504136Foot switch to start a MEP stimulationFoot switch with USB connection, grey, non-sterile, wipe-disinfectable
Available
Add to watch list
LED flash goggles for VEP stimulation
Item no.: 505055LED flash goggles for VEP stimulation6 red LEDs, touchproof connection, R/L labeling, delivered non-sterile, wipe-disinfectable
Available
Add to watch list
Mute Sensor for suppression of HF noise
Item no.: 510025Mute Sensor for suppression of HF noiseFor use with C2 Xplore and IOM systems, delivered non-sterile, can be disinfected
Available
Add to watch list
Application accessories
NeurosurgeryFurther accessories for the application field

Available
Spine surgeryFurther accessories for the application field

Available
Vascular surgeryFurther accessories for the application field

Available
NeuroExplorer 8

All IOM systems are equipped with the new, particularly flexible NeuroExplorer software generation

32-channel system with maximum equipment

The Xpert plus 32 Ch., the system for multimodal intraoperative neurophysiological monitoring, can be used in various application fields thanks to its easy handling and versatility. It offers a wide range of integration possibilities, such as a connection to the microscope or a link to the hospital information system (HIS).

Product features

HL7 integration for HIS connection
HL7 integration for HIS connection
HIS integration
Thanks to the connection, patient data can easily be uploaded from the HIS to the NeuroExplorer software. After monitoring, the PDF report can be filed with the patient data stored in the HIS.
The Xpert plus can be connected to the hospital information system (HIS) via the hospital network.
German patented technology for stimulation artifact suppression
German patented technology for stimulation artifact suppression
Stimulation artifact suppression
The German patented technology for the suppression of stimulation artifacts also allows signals with short latency and low amplitude to be displayed. Whether D-wave or corticobulbar MEPs: less superimposition makes it easier to identify the signals.
Stimulation artifact suppression also allows signals with a short latency and low amplitude to be displayed.
Ready for use in research
Ready for use in research
Ideal for research purposes
The Xpert plus is ideal for use in research. It has trigger in/out connections and various options for exporting curves or raw data.
The Xpert plus is ideal for use in research.
Maximum interconnection and facilitated data transport
Maximum interconnection and facilitated data transport
Digital connectivity
With comprehensive HL7 support, we enable efficient communication and data exchange between different hospital information systems, medical devices and medical staff. Further integration possibilities, such as tablet use, printer connection or facilitated network integration, communicate wirelessly with each other. This leads to seamless and improved patient care, as the relevant data is made available in real time.
Possibility of full HL7 integration into the hospital network. Establishes the interface between the HIS and the IONM device.

Extension options

Each IOM system can be upgraded to up to 64 (inomed Xpress 48) channels with additional amplifier and recording boxes (Headboxes). The following options are available:
 
Recording + AEP stimulation:  
ISIS Headbox 8Ch. DIF - 8Ch. REF - AEPItem no. 504285: 8 referential channels (e.g. VEP, EEG, SEP) + 8 differential channels (e.g. EMG, MEP)
ISIS Headbox 16Ch. REF - AEPItem no. 504281: 16 referential channels
 
Recording only: 
ISIS Headbox 16 Ch. DIFItem no. 504271: 16 differential channels
ISIS Headbox 16Ch. REFItem no. 504261: 16 referential channels
  
 

Relevant procedures

Relevant application fields

FAQ

Can the position of the ISIS Xpert plus screen be changed?

Yes, the screen height can be adjusted hydraulically to suit the user. The screen can also be rotated approximately 180 degrees in both directions.

Is it possible to display the image of the surgical microscope on inomed Xpert and inomed Xpert plus?

Yes, the video module can be used to connect surgical microscopes to the Xpert and Xpert plus. The connection is realized via an SDI cable. The microscope image can then be displayed in the NeuroExplorer software.

What are the differences between inomed Xpert and inomed Xpert plus?

The differences are the equipment and the software packages included in the standard versions.