ISIS NeurostimulatorThe ISIS Neurostimulator is a multifunctional constant current stimulator specially designed for intraoperative neurostimulation. It offers 12 high-current (0.2–250 mA) and one low-current (0.01–25 mA) stimulation channels. It can be used in combination with the ISIS IOM systems and the NeuroExplorer software or as as single device with its own stimulation software.
ISIS NeurostimulatorISIS Neurostimulator
ISIS NeurostimulatorThe ISIS Neurostimulator is a multifunctional constant current stimulator specially designed for intraoperative neurostimulation. It offers 12 high-current (0.2–250 mA) and one low-current (0.01–25 mA) stimulation channels. It can be used in combination with the ISIS IOM systems and the NeuroExplorer software or as as single device with its own stimulation software.


Variants
ISIS Neurostimulator
Item no.: 504180ISIS NeurostimulatorConstant current stimulator, 1-channel direct nerve stimulator: 0.01 to 25 mA, 12-channel high current stimulator: 0.2 to 250 mA, for use with inomed software. Can be combined with: 540501, 540511, 540510, 540559, 540560
Available
Go to product page
Add to watch list
ISIS Neurostimulator Complete System
Item no.: 504185ISIS Neurostimulator Complete SystemISIS Neurostimulator Complete System with ISIS Neurostimulator Software, notebook incl. medical power supply, connection cable and stimulation adaptor 540501
Available
Go to product page
Add to watch list
Extensions
Stimulation Adaptor for ISIS Neurostimulator
Item no.: 540511Stimulation Adaptor for ISIS NeurostimulatorFor 8-channel high-current stimulation. Can be combined with: 504180
Available
Add to watch list
SEP Stimulation Adaptor for ISIS Neurostimulator
Item no.: 540501SEP Stimulation Adaptor for ISIS Neurostimulator4-channel high-current stimulation and 1-channel direct nerve stimulation (DNS). Can be combined with: 504180
Available
Add to watch list
Grid/TES Stimulation matrix 8 Ch. for ISIS Neurostimulator
Item no.: 540559Grid/TES Stimulation matrix 8 Ch. for ISIS NeurostimulatorFor interconnection of up to 8 electrode contacts for cortical stimulation and up to 6 electrodes for transcranial electrical stimulation using high-current stimulation, with LED illumination. Can be combined with: 540523, 540525, 540510, 504180
Available
Add to watch list
Grid/TES Stimulation matrix 16 Ch. for ISIS Neurostimulator
Item no.: 540560Grid/TES Stimulation matrix 16 Ch. for ISIS NeurostimulatorFor interconnection of up to 16 electrode contacts for cortical stimulation and up to 6 electrodes for transcranial electrical stimulation using high-current stimulation, with LED illumination. Can be combined with: 540522, 540524, 540510, 504180
Available
Add to watch list
MEP Stimulation Adaptor for Grid/TES Stimulation matrix
Item no.: 540510MEP Stimulation Adaptor for Grid/TES Stimulation matrixFor 8-channel high-current stimulation for connection to Grid/TES stimulation matrix. Can be combined with: 504180, 540559, 540560
Available
Add to watch list

Maximum flexibility

The 12 channels for high current stimulation (max. 250 mA) and one channel for direct nerve stimulation (max. 25 mA) allow the use of different neurophysiological measurement methods in neurosurgery, epilepsy surgery, general and visceral surgery as well as otorhinolaryngology. The stimulation current can be set in individually definable steps from 0.2 to 250 mA (high current) and 0.01 to 25 mA (direct) and can take the form of a monophasic, biphasic or alternating pulse.

Product features

Free pulse configuration for maximum flexibility
Free pulse configuration for maximum flexibility
Free pulse configuration
In the free pulse configuration, any number of pulses of different polarity, current and pulse duration can be strung together with and without a break.
The Neurostimulator as a single device and the associated software make it easy to programme an unlimited number of application-specific stimulation programmes.
German patented technology for stimulation artefact suppression
German patented technology for stimulation artefact suppression
Stimulation artefact suppression
The German patented technology for the suppression of stimulation artefacts also allows signals with short latency and low amplitude to be displayed. Whether D-wave or corticobulbar MEPs: less superimposition makes it easier to identify the signals.
Stimulation artefact suppression also allows signals with short latency and low amplitude to be displayed.
Electrical promontory test for the indication of different hearing disorders
Electrical promontory test for the indication of different hearing disorders
Wide range of research applications
For the test, a weak stimulation current is emitted to a transtympanic electrode via the Neuro­stimulator, whereby the E-BERA curve is recorded using an external device and then analysed.
The flexible programmability of the stimulation sequences establishes the Neurostimulator as a stand-alone application in a variety of research areas, such as epilepsy surgery and the performance of electrical promontory tests.

Relevant procedures

Subcortical motor mapping
Neurosurgery
Subcortical motor mapping
During neurosurgical procedures in the motor cortex and motor pathways, precise work is of utmost importance. To avoid damaging functional structures during tumour resection or haemostasis, it is ...
Vestibular schwannomas
Neurosurgery
Vestibular schwannomas
Surgical treatment of vestibular schwannomas is challenging for many reasons. Not only positioning, access route and wound closure require special care, but also the intraoperative protection of the ...
Scoliosis
Spine surgery
Scoliosis
Surgical treatment of spinal deformities with curvature and rotation (scoliosis) requires a great deal of sensitivity and patience. The most important tasks are to insert the implants precisely and ...
Lateral access to the spine
Spine surgery
Lateral access to the spine
The lateral access to the lumbar spine has the advantage that both the intervertebral disc space and the vertebral bodies can be worked on and the sensitive cauda fibres do not restrict the surgical ...
Thyroid surgery
General surgery
Thyroid surgery
The cutting-edge ALM (Advanced Laryngeal Monitoring) technology provides reliable signal recording through the interaction of an electrode tube and intelligent software. The 360° electrode surface ...
Autofluorescence of the parathyroid glands
General surgery
Autofluorescence of the parathyroid glands
(Auto)fluorescence technology can be used to spare the parathyroid glands during thyroid or parathyroid surgery and to check their vascularisation. With the FLUOBEAM® LX, developed specifically for ...
Thyroid nodules
Ablation
Thyroid nodules
Radiofrequency ablation is a gentle thermoablative procedure in which diseased tissue is destroyed by a high-frequency current. The healthy surrounding tissue is preserved. The RFA is carried out ...
All procedures of our products 

Relevant application fields

Neurosurgery
Application Field
Neurosurgery
Neurosurgery deals with the detection and surgical treatment of diseases, malformations and injuries of the central and peripheral nervous system. Maintaining the nervous system’s functions during ...
Spine surgery
Application Field
Spine surgery
Spine surgery is a cross-disciplinary field that encompasses neurosurgical, orthopaedic and trauma surgery aspects. Ideally, all specialist disciplines work together to provide the best possible ...
Vascular surgery
Application Field
Vascular surgery
Vascular surgery is dedicated to the treatment of various diseases of blood vessels. Intraoperative neuromonitoring plays an important role in this application field, especially during surgery of ...
Pelvic intraoperative neuromonitoring
Application Field
Pelvic intraoperative neuromonitoring
Pelvic intraoperative neuromonitoring enables electrophysiological monitoring of nerve functions during surgical interventions in the small pelvis. pIOM® has been proven to improve functional ...
Thyroid surgery
Application Field
Thyroid surgery
The cutting-edge ALM (Advanced Laryngeal Monitoring) technology combines highly precise signal recording in thyroid surgery with intelligent software to provide a reliable nerve response signal. More ...
ENT surgery
Application Field
ENT surgery
Ear, nose and throat surgery includes many nerve-sparing procedures, which means that intraoperative neuro­moni­toring (IONM) plays an important role in protecting the facial nerve. IONM is ...
All application fields of our products 

FAQ

Is the ISIS Neurostimulator a constant current stimulator or a constant voltage stimulator?

The ISIS Neurostimulator is a constant current stimulator.